CHINA RECOGNIZED INTRENATIONAL MUTUAL RECOGNITION TEST TESTING CNAS L13989

English

中文(简体)

中文(繁體)

English

ROHS2.0 detector, thermal cracking ROHS detector, phthalate detection instrument

Pyrolysis chromatography is an effective analytical technique that can decompose non-volatile molecules into fragments suitable for gas phase analysis by heating. This produces a reproducible characteristic fingerprint of a non-volatile sample. This technique can be applied in many different fields, including polymer science, microbiology, bioengineering, medicine and health, forensic inspection, energy, geology and geochemistry. It can analyze high molecular polymers, rubber, various fibers, coatings, and perform qualitative analysis in the fields of petrochemicals, food, medicine, public security, etc.; information on the composition and structure of coatings, rubber, and polymers; identification of the content and structure of each component in chemicals.
  • Expedited evaluation service
  • Fair and just, low cost
Process

Advantages

    As phthalates are included in the RoHS 2.0 regulations, testing laboratories are considering which test methods to use to deal with new laws and regulations. The main requirements of ROHS2.0 users for testing include: convenient and simple testing, low educational requirements for operators, and reliable results. Secondly, consider the purchase cost. Among various testing methods, Tianke Instruments has launched a set of thermal pyrolysis chromatography Py-GC solutions, which has reliable test results for system performance issues.

    • Easy operation, no worries for novices
    • Professional screening software, easy operation
    • Say goodbye to organic solvents
    • Standard curve built into the software, analysis results are clear at a glance
    • Professional full set of equipment and tools
    • Special standard products
    • Simple instrument maintenance
    • Software built-in maintenance wizard
    • Provide long-term maintenance consumables package
    • Professional test data software for pyrolysis desorption instrument







Usage Advantage

    • Environmental impact assessment: No pre-treatment is required, no hazardous chemical reagents, no waste gas or waste liquid is generated, and no application for environmental impact assessment is required;

    • Site: No need to build a professional laboratory, an operating table of about 2 meters, equipped with air conditioning;

    • Staffing: 1 operator is required, who knows basic computer operations;

    • Short sample preparation time: 20 minutes, the result time fully meets the rapid screening needs of corporate users;

    • Low procurement cost: PY+GCMS procurement cost is 1 million, GC-MS procurement cost is about 450,000, and UPY procurement cost is less than 200,000;

    • Low use cost: No pre-treatment is required, only a small amount of safety reagents and consumables are required, and the annual use cost is less than 2,000 yuan;

    • Convenient and fast: Direct solid or liquid injection, five-step operation to get the result;

    • Built-in standard curve: More intuitive judgment of whether the material exceeds the phthalate standard, no need to inject standard samples every day.

    • Applicable materials: Chemical methods are only applicable to 70% of materials, while UPY is applicable to 90% of materials;


Instrument Features

  • The whole instrument has been completely redesigned, with a grand appearance, reasonable structure, modular design and easy maintenance;
  • Vacuum fluorescent display technology has been loaded; the interface operation is more suitable for China's national conditions;
  • The traditional mechanical valve and pointer pressure gauge have been completely abandoned! The full EPC technology is used for gas circuit control, which greatly improves its automation level and overall performance. It realizes automatic protection of gas circuit failure, automatic ignition, and automatic execution of the opening of the switch gas circuit;
  • 15-way EPC and EFC control modules can be loaded, which can meet the complex configuration of dual capillary injectors and three detectors;
  • 6 independent temperature control areas;
  • 8 independent external event controls, which can configure complex external event controls;
  • Intelligent rear door opening technology can achieve rapid cooling of the main box temperature and shorten the analysis waiting time; it takes 8 minutes to reduce from 350℃ to 50℃;
  • Support network port communication, which can realize remote data transmission; The system is designed with an automatic sampler interface to facilitate the connection of the automatic sampler and future upgrades.



Main Technical Indicators

  • Operation display: vacuum fluorescent display screen
  • Temperature control area: 6 channels
  • Temperature control range: 4℃~450℃ above room temperature, increment: 1℃, accuracy: ±0.1℃
  • Program temperature rise steps: 16 steps
  • Program rise rate: 0.1~39℃/min (ordinary type); 0.1~80℃/min (high-speed type)
  • External events: 8 channels; auxiliary control output 4 channels
  • Injector type: packed column injection, capillary injection, six-way valve gas injection, automatic headspace injection
  • Number of detectors: 3 (maximum); (FID, TCD, ECD, FPD, NPD) optional
  • Gas path control: full EPC
  • EPC, EFC working modes: 2 types; constant flow mode, constant pressure mode
  • EPC, EFC working gases: 5 types; nitrogen, hydrogen, air, helium, argon
  • EPC, EFC program rise: 4
  • EPC, EFC control range:
  • Pressure: 0~0.6Mpa; flow 0~100sccm or 0~500sccm (air)
  • EPC, EFC control accuracy: pressure 0.01Kpa; flow 0.01sccm
  • Pressure sensor: Accuracy: <±2% of full scale Reproducibility: <±0.05 KPa
  • Temperature coefficient: <±0.01 KPa/°C Range: 0~0.3MPa or 0~0.6MPa;
  • Flow sensor: Accuracy: <±5% of full scale Reproducibility: <±0.5% (full scale) Range: 0~500sccm
  • Start injection: (manual, automatic, syringe automatic detection) optional
  • Communication interface: Ethernet: IEEE802.3
  • Hydrogen flame ionization detector (FID)
  • Detection limit: Mt≤3×10-12g/s (n-hexadecane-isooctane solution);
  • Baseline noise: ≤5×10-14A Baseline drift: ≤1×10-13A/30min
  • Linear range: ≥106 Maximum operating temperature: ≤450℃



Main Technical Indicators Of Cracking Pool

  • Cracking pool temperature range: 10~600℃ above room temperature, adjustable in increments of 10℃.
  • Cracking chamber heating rate: 15℃/S.
  • Cracking chamber temperature control time: 0.1min~999min adjustable
  • 7-inch true color touch screen, built-in 10 storable method files
  • Analysis result repeatability: ≤2%. (Polystyrene dimer).
  • Dimensions: 400mmX160mmX400mm (length X width X height).
  • Maximum power: 300W.

Process

Testing Process

As an internationally professional third-party testing organization, ATS's management system is established and implemented in strict accordance with ISO/IEC17025:2017 "General Requirements for the Competence of Testing and Calibration Laboratories".

  • Speed of Phone Calls

    As an internationally professional third-party testing organization, ATS's management system strictly complies with ISO/IEC17025:2017

  • Send you Samples

    As an internationally professional third-party testing organization, ATS's management system strictly complies with ISO/IEC17025:2017

  • To Complete the Payment

    As an internationally professional third-party testing organization, ATS's management system strictly complies with ISO/IEC17025:2017

  • Send the Quotation

    As an internationally professional third-party testing organization, ATS's management system strictly complies with ISO/IEC17025:2017

  • Fill Out the Application

    As an internationally professional third-party testing organization, ATS's management system strictly complies with ISO/IEC17025:2017

  • Arrange Test

    As an internationally professional third-party testing organization, ATS's management system strictly complies with ISO/IEC17025:2017

  • Finish the Report

    As an internationally professional third-party testing organization, ATS's management system strictly complies with ISO/IEC17025:2017

  • Technical Support

    As an internationally professional third-party testing organization, ATS's management system strictly complies with ISO/IEC17025:2017

Services

More Services

View More

    If you have any questions, you can contact our relevant staff by email/phone to obtain relevant information.